Dicom Converter for Toshiba XVision , XPress non-DICOM CT

Native Dicom Converters for Toshiba non-dicom CT

MILLENSYS Xlink gateway is a system that accepts ACR/NEMA 1.0 images [Raw Data] from any Toshiba X-Series CT Scanner [Xpeed, Xvision, Xpress, ....] and Toshiba MRI [FlexArt, VisArt, ExcelArt,...] transferred using the [Xlink] protocol and convert it to DICOM 3.0 format and  insert the patient study in Vision Tools system directly in a transparent way. The solution is very innovative in that Toshiba X-Series machines only transfer images using ACR/NEMA 1.0 format, this format is no longer supported by newer DICOM 3.0 compatible stations.

Advantages

  • No need to use frame grabber cards to grab the images from the modalities [no raw data only 8 bit].
  • All images converted with our MiXlink gateway uses all the resolution of the raw data [12 bit, 16 bit]  
  • The system accepts multi CT modalities connected to the same MiXlink station

Dicom Converter for Toshiba Flexart , Visart non-dicom MRI

Native Dicom Converters for Toshiba non-dicom MRI

MILLENSYS Xlink gateway is a system that accepts ACR/NEMA 1.0 images [Raw Data] from any Toshiba X-Series CT Scanner [Xpeed, Xvision, Xpress, ....] and Toshiba MRI [FlexArt, VisArt, ExcelArt,...] transferred using the [Xlink] protocol and convert it to DICOM 3.0 format and  insert the patient study in Vision Tools system directly in a transparent way. The solution is very innovative in that Toshiba X-Series machines only transfer images using ACR/NEMA 1.0 format, this format is no longer supported by newer DICOM 3.0 compatible stations.

Advantages

  • No need to use frame grabber cards to grab the images from the modalities [no raw data only 8 bit].
  • All images converted with our MiXlink gateway uses all the resolution of the raw data [12 bit, 16 bit]  
  • The system accepts multi CT modalities connected to the same MiXlink station

Dicom Converter for Toshiba Auklet non-dicom CT

Native Dicom Converters for Toshiba non-dicom CT

MILLENSYS MiTOS Software is a system that accepts ACR/NEMA 1.0 images [Raw Data] from any Toshiba A-Series CT Scanner [Auklet, Asteion, Aquilion, ...] and convert it to DICOM 3.0 format and  insert the patient study in Vision Tools system directly in a transparent way. The solution is very innovative in that it is much cheaper than Toshiba A-Series DICOM option and more featured.

Advantages

  • No need to use frame grabber cards to grab the images from the modalities [no raw data only 8 bit].
  • All images converted with our MiTOS gateway uses all the resolution of the raw data [12 bit, 16 bit]  

Dicom Print Converter for Toshiba non-dicom MRI and NM

Native Dicom Converters for Toshiba non-dicom MRI, NM

Keni2Dicom print gateway is a system that accepts ACR/NEMA 2.0 images from any Toshiba MRI [Flexart, Visart, etc...] or Toshiba Gamma Camera Machines and prints the received images directly to any Dicom Printers [wet or dry]. The solution is very innovative in that Toshiba MRI and NM machines only print images using ACR/NEMA 2.0 format, this format is no longer supported by newer DICOM 3.0 compatible printers